Batterlution DC load banks feature a controlled, stepped-adjustment design, purpose-built for battery bank discharging, actual capacity verification, and DC power supply testing in telecommunications, data centers, utilities, and industrial environments. This series offers manually selectable resistive loads, making it suitable for a wide range of DC power testing applications. With six distinct configurations—from compact 24V units to 260kW industrial-grade systems—we can meet the complex testing requirements of diverse users. We also welcome custom requests; our experienced engineers are ready to design and manufacture a load bank tailored specifically to your unique needs.
Standard Voltage Range
Maximum Current
Maximum Capacity
Duty cycle
A DC load bank is a standalone, resistive load-testing device. It draws power from a DC source—such as a battery bank, UPS bus, telecommunications power system, charger, or other DC power equipment—and directs it into the load bank, where the energy is converted into heat by resistive elements and dissipated via a controlled, air-cooled system. By simulating a stable and measurable load, the device allows engineers to quickly and intuitively observe how their equipment performs under real-world operating conditions, ultimately saving significant time and costs during the pre-deployment testing phase.
Batterlution DC load banks are specifically designed for capacity acceptance testing, preventive maintenance discharge testing, and commissioning of power systems. They feature programmable buttons and a touchscreen interface for adjusting load levels and monitoring data. Built-in instrumentation provides real-time displays of voltage, current, and operating duration, while integrated over-temperature and over-current protection ensure the safety of both the test equipment and the system under test. All standard models are designed for continuous operation and are equipped with casters, facilitating easy movement between different testing locations.
Standard DC load bank models cover 24 VDC to 260 VDC. Every rating below can be customized in voltage, current, load steps and cabinet format for your test requirement.
Voltage
Current
Capacity
Compact bench-type resistive load bank for 24 VDC battery discharge and DC supply testing.
Voltage
Current
Capacity
Compact bench-type resistive load bank for 24 VDC battery discharge and DC supply testing.
Voltage
Current
Capacity
48 VDC telecom and UPS battery testing load bank with horizontal forced-air cooling.
Voltage
Current
Capacity
Cabinet-format 48 VDC high-current unit for large battery string discharge tests.
Voltage
Current
Capacity
Medium-voltage DC testing cabinet for industrial and substation battery systems.
Voltage
Current
Capacity
Our largest standard DC resistive load bank for high-power DC source commissioning.
Model |
Nominal Voltage |
Max Current |
Capacity |
Cooling Supply |
Size L×W×H (mm) |
Weight |
|---|---|---|---|---|---|---|
|
DC-24V300 |
24 VDC |
300 A |
7.2 kW |
Internal 24VDC fan |
500 × 280 × 300 |
50 kg |
|
DC-24V600 |
24 VDC |
600 A |
14.4 kW |
Internal 24VDC fan |
500 × 280 × 300 |
55 kg |
|
DC-48V600 |
48 VDC |
600 A |
28.8 kW |
Internal 24VDC fan |
500 × 400 × 400 |
60 kg |
|
DC-48V1000 |
48 VDC |
1000 A |
48 kW |
Internal 24VDC fan |
600 × 450 × 400 |
80 kg |
|
DC-130V1000 |
130 VDC |
1000 A |
130 kW |
External 230V 1Ph 50/60 Hz |
750 × 500 × 600 |
180 kg |
|
DC-260V1000 |
260 VDC |
1000 A |
260 kW |
External 230V 1Ph 50/60 Hz |
1300 × 600 × 1200 |
230 kg |
Each of our DC load banks incorporates proven resistive technology, multi-stage control, and robust protection mechanisms. Housed in a durable, rugged enclosure, they are specifically engineered to meet the demands of frequent on-site testing.
High-temperature nickel-chromium finned resistor elements selected for long discharge cycles and stable, repeatable resistance.
Independent load steps switched from the local control panel with rotary knobs, giving precise, repeatable current staging without external automation.
Integrated metering display shows real-time voltage, current and operating time throughout the discharge test.
Dual protection trips the load before resistor or supply damage; units are rated IP23 for indoor and sheltered-site use.
Horizontal inlet and outlet airflow keeps elements within temperature limits during sustained discharge. Low-voltage units use an internal 24 VDC fan; high-voltage units use a 230 V 1Ph 50/60 Hz external fan supply.
Q235 steel cabinet in RAL7035 gray, fitted with four castors and load cable connectors; packed in a wooden case on a wooden pallet for export shipment.
In practical applications that require the verification and evaluation of features, or the debugging of systems for storing and supplying DC power, our DC load banks provide the controlled load simulation necessary throughout the entire process.
01
Controlled discharge tests that measure true amp-hour capacity against nameplate ratings.
02
Verify UPS battery runtime and expose early failure risk before mains loss.
03
Routine discharge testing of 48 VDC telecom battery strings at base stations and central offices.
04
Test control, protection and tripping battery banks in utility and industrial substations.
05
Verify chargers, converters and DC power supplies under defined load conditions.
06
Commissioning and capacity verification of stationary storage battery systems.
07
Discharge and acceptance testing of DC battery systems on board vessels and offshore platforms.
08
Load testing of industrial traction battery packs prior to service or refurbishment.
Our cabinets are constructed from high-quality Q235 steel sheets, assembled using screws. The surfaces are finished with a durable, rust-resistant epoxy-polyester powder coating in RAL 7035—a classic, industry-standard color for electrical enclosures.
Power cable connectors are positioned on the rear and side panels, facilitating easy parallel connection with other equipment. Internal components—including resistor banks, cooling fans, the control panel, and access doors—are partitioned from one another, achieving an IP23 ingress protection rating.
For high-current applications, cooling is provided by fans powered by a single-phase 230V supply; for smaller-scale 24V and 48V units, the cooling fans are powered directly by the DC bus under test. This design effectively addresses the intensive cooling requirements of large-scale equipment while maintaining a compact cooling solution for smaller units.
A DC load bank simulates the actual operating conditions of field equipment powered by a DC source by applying a controllable external resistance. This allows for the testing and verification of a DC power supply's performance under specific load conditions. Common applications for DC load banks include battery capacity and discharge testing, maintenance of UPS (Uninterruptible Power Supply) and telecommunication batteries, commissioning of batteries in substations, and the testing of chargers and DC power supplies.
Our standard range spans 24 VDC, 48 VDC, 130 VDC and 260 VDC, with currents from 300 A to 1000 A and capacities from 7.2 kW to 260 kW. Ratings outside this range can be engineered to order.
Yes. All of our DC load banks are resistive; the energy from the DC power source is converted into heat by nickel-chromium alloy finned resistor elements, which is then dissipated via air cooling using internal fans. At present, our load banks cannot simulate inductive or capacitive loads.
Yes. In addition to the standard models featured on our website, we can also provide custom DC load cabinets tailored to your specific requirements—including voltage, current, load-stepping configuration, and cabinet enclosure style. Please share your technical specifications with us via the form on our website or by emailing info@butterlation.com, and we will promptly provide you with a suitable configuration proposal.
Each of our DC load banks is equipped with over-temperature and over-current protection, and comes standard with a power metering display and load cable connectors. The enclosure features an IP23 ingress protection rating, and all standard models are designed for continuous, long-term operation.
You may choose to purchase our standard DC load banks for immediate use, or provide us with your technical specifications so we can design a customized load bank tailored to your specific on-site equipment. Our DC load banks are suitable for a wide range of applications, including testing for data center UPS battery systems, 48V DC telecommunication power systems, electrical substations, battery energy storage systems (BESS), as well as marine and traction batteries. All products are shipped in export-compliant packaging that meets global transport standards, with custom packaging options also available upon request.