Most custom load bank inquiries start with one mismatch: the catalog model is close, but it does not fit the real site, test method or buyer's documentation needs.
Voltage, frequency, phase, load step resolution, AC/DC input or test duration does not match an off-the-shelf unit.
The project requires air cooling, liquid cooling, coolant flow control, pressure limits, ducting or a site-specific heat rejection path.
The load bank must fit a rack, cabinet, skid, outdoor frame, container, restricted space or OEM-branded enclosure.
The test plan needs PLC, HMI, Modbus, remote control, automatic sequences, alarm records or Excel/PDF report export.
The buyer needs FAT records, wiring drawings, packing lists, operation manuals or project-specific inspection reports.
The project needs a repeatable design for distributors, integrators or private-label manufacturing.
Start with the test job, site conditions and control needs. These seven points usually decide the right load bank design.
Start with the real test scenario so the load bank is designed for the correct duty.
Data center, UPS, Generator, Battery, CDU, Factory test
Choose the electrical and cooling architecture before confirming the enclosure.
AC, DC, Resistive, Regenerative, Air-cooled, Liquid-cooled
Define the rating and test profile clearly to avoid undersized or overbuilt equipment.
kW/kVA/MW, Voltage, Current, Phase, Load steps, Duration
Cooling design affects stability, site preparation, safety protection and maintenance.
Forced air, Coolant flow, Inlet temp, Outlet temp, Pressure, Heat rejection
Match the mechanical format to the space, service path and deployment environment.
Rack, Cabinet, Skid, Mobile frame, Outdoor, Container
Confirm how operators will run tests, collect records and integrate with site systems.
PLC, HMI, Remote, Modbus, Ethernet, Reports
Voltage, current, AC/DC design, load steps, power range and test duration.
Rack, cabinet, skid, container, cable entry, hose connection and service access.
Emergency stop, over-temperature, low-flow, leakage, phase loss and interlocks.
PLC, HMI, remote control, Modbus, Ethernet, data logging and reports.
Air cooling, liquid cooling, airflow, coolant flow, pressure and temperature range.
Factory tests, alarm checks, FAT records, wiring drawings and manuals.
The more complete the RFQ information is, the faster our engineering team can recommend the right load bank architecture, enclosure and control plan.
Required information |
Example |
|---|---|
|
Application |
Data center commissioning, CDU testing, UPS test, generator test, battery discharge or production test bench. |
|
Load capacity |
100 kW, 500 kW, 1 MW, 5 MW or staged capacity by test profile. |
|
Voltage and phase |
400 V 3-phase, 480 V 3-phase, medium voltage through transformer, or DC voltage range. |
|
Cooling method |
Air-cooled, liquid-cooled, coolant type, flow rate, pressure range and inlet/outlet temperature. |
|
Installation |
Rack-mounted, cabinet, skid, mobile frame, outdoor container or fixed test room installation. |
|
Control method |
Manual switching, PLC, HMI, PC software, remote control, Modbus RTU/TCP, Ethernet or SCADA integration. |
|
Environment |
Indoor, outdoor, high humidity, high altitude, low noise requirement, limited space or transport requirement. |
|
Documentation |
FAT report, wiring diagram, layout drawing, packing list, user manual, calibration/test report and OEM label files. |
For overseas B2B partners, the deliverable is not only the load bank hardware. A complete custom project should include engineering data, test records and production documents that make resale, integration and after-sales support easier.
Configuration summary, electrical/cooling concept, control plan, estimated dimensions and quotation basis.
Layout review, interface confirmation, cabinet color, label language, communication protocol and safety logic approval.
Load step verification, control response, alarm checks, temperature/flow records and pre-shipment inspection.
Operation manual, wiring diagram, checklist, packing information and project-specific test report template.
Reinforced packaging, shipment marking, accessory list and export-oriented protection for long-distance transport.
Spare parts advice, troubleshooting support, software updates and upgrade planning for repeat orders.
Yes. Batterlution designs and manufactures custom built load banks for AC/DC testing, data center commissioning, UPS testing, generator testing, liquid-cooled applications, rack-mounted systems and containerized projects.
A custom built load bank is designed around project-specific power rating, voltage, cooling method, enclosure, control logic, communication interface and testing application instead of using a standard catalog model.
Yes. Batterlution can design rack-mounted, cabinet, skid-mounted, outdoor, stainless steel and containerized enclosures with project-specific airflow, cable entry, hose connection, lifting, service access and branding requirements.
Yes. Batterlution supports liquid-cooled custom load banks for data center commissioning, CDU testing, cooling loop validation and high-density server heat load simulation.
Yes. PLC control, HMI, PC software, remote control, Modbus RTU, Modbus TCP, data logging, alarm records and automatic test workflows can be customized.
A load bank becomes custom built when its power rating, voltage, cooling method, enclosure, installation format, control system, communication protocol, reporting workflow or safety logic is designed around a specific project instead of a standard catalog model.
A custom built load bank is useful when the project requires a non-standard voltage, power range, duty cycle, enclosure, installation method, cooling system, control interface, reporting workflow or OEM branding.
Please provide application, load capacity, voltage, phase, frequency, cooling method, installation type, control method, communication interface, duty cycle, environment, documentation requirements, quantity and target delivery schedule.